Reliability  Safety  Capacity

Solis-(25-30)K-LV

220V: 25K-LV/30K-L

Solis-(25-30)kW three-phase series string inverter are suitable for the installation of three-phase input pv system of commercial and industrial PV plants. WhoseTHDi˂3, low harmonic distortion against grid. Adopt anti-resonance,signle transformer can connect 6M+ in parallel. Perfect commercial site monitoring solution, intelligent redundancy fan.

25-30 kW Three Phase Inverter

Leading Features

  • Max. efficiency 97%
  • Intelligent redundant fan-cooling
  • Wide voltage range and low startup voltage
  • THDi<3%, low harmonic distortion against grid
  • Perfect commercial site monitoring solution
  • 2 MPPT input, each rated current is 28.5 A, compatible with high power module
  • Anti-resonance, supporting over 6MW parallelled in one transformer

Technical Specifications

Input DC

  • Rated voltage
    600 V
  • Start-up voltage
    200 V
  • MPPT voltage range
    200-850 V
  • Max. input current
    28.5 A / 28.5 A
  • Max. short circuit current
    44.5 A / 44.5 A
  • MPPT number
    2
  • Max. input strings number
    6

Output AC

  • Max. apparent output power
    25 kVA
  • Max. output power
    25 kW
  • Rated grid voltage
    3/PE, 220 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    65.6 A
  • Max. output current
    65.6 A
  • Power Factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    96.5%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    Yes
  • Grid monitoring
    Yes
  • Anti-islanding protection
    Yes
  • Temperature protection
    Yes
  • Integrated DC switch
    Optional

General Data

  • Weight
    63 kg
  • Topology
    Transformerless
  • Self consumption (night)
    <1 W
  • Operating ambient temperature range
    -25 ~ +60°C
  • Relative humidity
    0-100%
  • Ingress protection
    IP65
  • Cooling concept
    Intelligent redundant fan-cooling
  • Max.operation altitude
    4000 m
  • Grid connection standard
    EN 50549-1, EN50438, C10/11, G99, VDE-AR-N 4105 / VDE V 0124, NBR 16149, NBR 16150, IEC 62116, IEC 61000-3-4/-5, IEC 61000-3-11/-12
  • Safety/EMC standard
    IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4

Features

  • AC connection
    OT terminal
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS
Sales Inquiries:sales@ginlong.com